Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Hum Gene Ther ; 24(3): 242-4, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23458444
3.
BMC Genomics ; 9: 258, 2008 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-18513391

RESUMO

BACKGROUND: Oligoarrays have become an accessible technique for exploring the transcriptome, but it is presently unclear how absolute transcript data from this technique compare to the data achieved with tag-based quantitative techniques, such as massively parallel signature sequencing (MPSS) and serial analysis of gene expression (SAGE). By use of the TransCount method we calculated absolute transcript concentrations from spotted oligoarray intensities, enabling direct comparisons with tag counts obtained with MPSS and SAGE. The tag counts were converted to number of transcripts per cell by assuming that the sum of all transcripts in a single cell was 5.105. Our aim was to investigate whether the less resource demanding and more widespread oligoarray technique could provide data that were correlated to and had the same absolute scale as those obtained with MPSS and SAGE. RESULTS: A number of 1,777 unique transcripts were detected in common for the three technologies and served as the basis for our analyses. The correlations involving the oligoarray data were not weaker than, but, similar to the correlation between the MPSS and SAGE data, both when the entire concentration range was considered and at high concentrations. The data sets were more strongly correlated at high transcript concentrations than at low concentrations. On an absolute scale, the number of transcripts per cell and gene was generally higher based on oligoarrays than on MPSS and SAGE, and ranged from 1.6 to 9,705 for the 1,777 overlapping genes. The MPSS data were on same scale as the SAGE data, ranging from 0.5 to 3,180 (MPSS) and 9 to1,268 (SAGE) transcripts per cell and gene. The sum of all transcripts per cell for these genes was 3.8.105 (oligoarrays), 1.1.105 (MPSS) and 7.6.104 (SAGE), whereas the corresponding sum for all detected transcripts was 1.1.106 (oligoarrays), 2.8.105 (MPSS) and 3.8.105 (SAGE). CONCLUSION: The oligoarrays and TransCount provide quantitative transcript concentrations that are correlated to MPSS and SAGE data, but, the absolute scale of the measurements differs across the technologies. The discrepancy questions whether the sum of all transcripts within a single cell might be higher than the number of 5.105 suggested in the literature and used to convert tag counts to transcripts per cell. If so, this may explain the apparent higher transcript detection efficiency of the oligoarrays, and has to be clarified before absolute transcript concentrations can be interchanged across the technologies. The ability to obtain transcript concentrations from oligoarrays opens up the possibility of efficient generation of universal transcript databases with low resource demands.


Assuntos
Perfilação da Expressão Gênica/métodos , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Animais , Etiquetas de Sequências Expressas , Camundongos , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Retina/metabolismo
4.
BMC Genomics ; 8: 153, 2007 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-17555589

RESUMO

BACKGROUND: High-throughput systems for gene expression profiling have been developed and have matured rapidly through the past decade. Broadly, these can be divided into two categories: hybridization-based and sequencing-based approaches. With data from different technologies being accumulated, concerns and challenges are raised about the level of agreement across technologies. As part of an ongoing large-scale cross-platform data comparison framework, we report here a comparison based on identical samples between one-dye DNA microarray platforms and MPSS (Massively Parallel Signature Sequencing). RESULTS: The DNA microarray platforms generally provided highly correlated data, while moderate correlations between microarrays and MPSS were obtained. Disagreements between the two types of technologies can be attributed to limitations inherent to both technologies. The variation found between pooled biological replicates underlines the importance of exercising caution in identification of differential expression, especially for the purposes of biomarker discovery. CONCLUSION: Based on different principles, hybridization-based and sequencing-based technologies should be considered complementary to each other, rather than competitive alternatives for measuring gene expression, and currently, both are important tools for transcriptome profiling.


Assuntos
Perfilação da Expressão Gênica/métodos , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Análise de Sequência de DNA/métodos , Análise de Variância , Animais , Biblioteca Gênica , Camundongos , Camundongos Endogâmicos C57BL , Hibridização de Ácido Nucleico
5.
Nat Biotechnol ; 24(7): 832-40, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16823376

RESUMO

Over the last decade, gene expression microarrays have had a profound impact on biomedical research. The diversity of platforms and analytical methods available to researchers have made the comparison of data from multiple platforms challenging. In this study, we describe a framework for comparisons across platforms and laboratories. We have attempted to include nearly all the available commercial and 'in-house' platforms. Using probe sequences matched at the exon level improved consistency of measurements across the different microarray platforms compared to annotation-based matches. Generally, consistency was good for highly expressed genes, and variable for genes with lower expression values as confirmed by quantitative real-time (QRT)-PCR. Concordance of measurements was higher between laboratories on the same platform than across platforms. We demonstrate that, after stringent preprocessing, commercial arrays were more consistent than in-house arrays, and by most measures, one-dye platforms were more consistent than two-dye platforms.


Assuntos
Mapeamento Cromossômico/métodos , Perfilação da Expressão Gênica/métodos , Análise em Microsséries/métodos , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Sondas de DNA/química , Sondas de DNA/classificação , Análise em Microsséries/classificação , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...